Diagnostic Procedure 3
- Check Security Indicator Power Supply Circuit
- Turn ignition switch OFF.
- Disconnect the security indicator lamp connector.
- Check voltage between security indicator lamp connector M73 terminal 2 (Y/G) and ground.
2 (Y/G) - Ground : Battery voltage
OK or NG
- OK : GO TO 2.
- NG : Check harness for open or short between fuse block and security indicator lamp.
- Check Security Indicator Ground Circuit
- Disconnect the NATS IMMU connector.
- Check continuity between security indicator lamp connector M73 terminal 1 (G) and NATS IMMU connector M32 terminal 15 (G).
1 (G) - 15 (G): Continuity should exist .
- Check continuity between NATS IMMU connector M32 terminal 15 (G) and ground.
15 (G) - Ground : Continuity should not exist .
OK or NG
- OK : GO TO 3.
- NG : Repair or replace harness.
- Check Security Indicator Ground Signal
- Connect NATS IMMU connector.
- Check continuity between NATS IMMU connector M32 terminal 15 (G) and ground.
15 (G)- Ground : Continuity should exist intermittently .
OK or NG
- OK : Replace security indicator lamp.
- NG : Replace NATS IMMU.