FixVault

5. Check Ho2S1 Connector For Water

  1. Turn ignition switch OFF.
  2. Disconnect heated oxygen sensor 1 harness connector.
  3. Check connectors for water.

    Water should not exist. 

OK or NG 

  1. OK: GO TO 6.
  2. NG: Repair or replace harness or connectors.