FixVault

Knock Sensor

Check resistance between knock sensor terminal 1 and ground.

NOTE: It is necessary to use an ohmmeter which can measure more than 10 MΩ.

Resistance: Approximately 530 - 590kΩ [at 20°C (68°F)] 

CAUTION: Do not use any knock sensors that have been dropped or physically damaged. Use only new ones.
Fig 1: Checking Resistance Between Knock Sensor Terminal 1 & Ground
G00795975Courtesy of NISSAN MOTOR CO., U.S.A.