FixVault

9. Check FPCM Output Signal Circuit For Open And Short

  1. Check harness continuity between ECM terminal 25 and FPCM terminal 1. Refer to WIRING DIAGRAM .

    Continuity should exist. 

  2. Also check harness for short to ground and short to power.

OK or NG 

  1. OK: GO TO 11. CHECK FPCM .