FixVault

With CONSULT-II

  1. Start engine and warm it up to normal operating temperature.
  2. Turn ignition switch OFF and wait at least 10 seconds.
  3. Turn ignition switch ON.
  4. Select "PURG VOL CN/V P1444" of "EVAPORATIVE SYSTEM" in "DTC WORK SUPPORT" mode with CONSULT-II.
    Fig 1: Scan Tool Display - DTC Work Support
    G00796433Courtesy of NISSAN MOTOR CO., U.S.A.
  5. Touch "START".
  6. Start engine and let it idle until "TESTING" on CONSULT-II changes to "COMPLETED". (It will take approximately 10 seconds.)

    If "TESTING" is not displayed after 5 minutes, retry from step 2. 

  7. Make sure that "OK" is displayed after touching "SELF-DIAG RESULTS". If "NG" is displayed, refer to DIAGNOSTIC PROCEDURE .