FixVault

4. Trunk Lid Close Switch Ground Circuit Check

Check continuity between trunk lid close switch connector B309 terminal 1 and ground.

  1. 1 (B) - Ground : Continuity should exist  .
Fig 1: Checking Continuity Between Trunk Lid Close Switch Terminal 1 And Ground
G00740996Courtesy of NISSAN MOTOR CO., U.S.A.

OK or NG 

  1. OK : Replace auto trunk control unit.
  2. NG : Repair or replace harness.