3. Check Ground Connections

  1. Turn ignition switch OFF.
  2. Loosen and retighten two ground screws.

    Refer to GROUND INSPECTION  .

OK or NG 

OK: GO TO 4.

NG: Repair or replace ground connections. See Figure.