Procedure For DTC P1124

TESTING CONDITION: 

Before performing the following procedure, confirm that battery voltage is more than 8V. 

With CONSULT-II 

  1. Turn ignition switch ON and wait at least 1 second.
  2. Select "DATA MONITOR" mode with CONSULT-II.
  3. If DTC is detected, go to DIAGNOSTIC PROCEDURE  .

With GST 