FixVault

3. Check HO2S2 Ground Circuit For Open And Short

  1. Turn ignition switch OFF.
  2. Disconnect heated oxygen sensor 2 harness connector.
  3. Check harness continuity between HO2S2 terminal 4 and ground.

    Refer to Wiring Diagram.

    1. Continuity should exist. 
  4. Also check harness for short to power.

OK or NG 

OK : GO TO 5.

NG : GO TO 4.