2. Check ECM Power Supply Circuit-I
- Turn ignition switch OFF and then ON.
- Check voltage between ECM terminal 53 and ground with CONSULT-II or tester.
- Voltage: Battery voltage
OK or NG
OK: GO TO 4. CHECK GROUND CONNECTIONS .
NG: GO TO 3.
OK or NG
OK: GO TO 4. CHECK GROUND CONNECTIONS .
NG: GO TO 3.