FixVault

With Consult-II

  1. Turn ignition switch ON and wait at least 1 second.
  2. Select "DATA MONITOR" mode with CONSULT-II.
  3. Shift selector lever to D position and wait at least 2 seconds.
  4. Shift selector lever to P position.
  5. Turn ignition switch OFF and wait at least 10 seconds.
  6. Turn ignition switch ON and wait at least 1 second.
  7. Shift selector lever to D position and wait at least 2 seconds.
  8. Shift selector lever to P position.
  9. Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
  10. If DTC is detected, go to DIAGNOSTIC PROCEDURE .
    Fig 1: Select "DATA MONITOR" Mode With CONSULT-II.
    G02691560Courtesy of NISSAN MOTOR CO., U.S.A.