FixVault

With Consult-II

  1. Reconnect harness connectors disconnected.
  2. Turn ignition switch ON.
  3. Perform "VIAS SOL VALVE  " in "ACTIVE TEST" mode.
  4. Check air passage continuity and operation delay time under the following conditions.
CONDITION VIAS SOL VALVE AND AIR PASSAGE CONTINUITY REFERENCE CHART

Condition VIAS SOL VALVE Air passage continuity between A and B Air passage continuity between A and C
ON Yes No
OFF No Yes

Operation takes less than 1 second. 

Fig 1: Checking Air Passage Continuity
G02358857Courtesy of NISSAN MOTOR CO., U.S.A.