Trunk Open Signal Check
- CHECK ELECTRONIC KEY TRUNK OPENING SIGNAL
Check voltage between auto trunk control unit connector B110 terminal 5 and ground.
OK or NG
- OK: TRUNK open signal is OK.
- NG: GO TO 2.
- CHECK HARNESS CONTINUITY
- Turn ignition switch OFF.
- Disconnect BCM and auto trunk control unit connector.
- Check continuity between BCM connector M4 terminal 1 and auto trunk control unit connector B110 terminal 5.
- 1 (G/Y) - 5 (G/Y): Continuity should exist.
- Check continuity between BCM connector M4 terminal 1 and ground.
- 1 (G/Y) - Ground: Continuity should not exist.
OK or NG
- OK: GO TO 3.
- NG: Repair or replace harness.
- CHECK AUTO TRUNK CONTROL UNIT OUTPUT SIGNAL
- Connect auto trunk control unit connector.
- Check voltage between auto trunk control unit connector B110 terminal 5 and ground.
- 5 (G/Y) - Ground: Approx. 5V
OK or NG
- OK: Check the condition of the harness and the connector.
- NG: Replace auto trunk control unit.