Fuel Pump Relay

Check continuity between terminals 3 and 5 under the following conditions.

FUEL PUMP RELAY CONTINUITY CONDITIONS

Conditions Continuity
12V direct current supply between terminals 1 and 2 Yes
No current supply No
Fig 1: Identifying Fuel Pump Relay Terminals And Circuit
G02369854Courtesy of NISSAN MOTOR CO., U.S.A.