Consult-II Basic Operation Procedure

CAUTION: If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be detected in self-diagnosis depending on control unit which carry out CAN communication.
  1. Turn ignition switch OFF.
  2. Connect CONSULT-II and CONSULT-II CONVERTER to data link connector.
    Fig 1: Identifying Data Link Connector
    G02383947Courtesy of NISSAN MOTOR CO., U.S.A.
  3. Turn ignition switch ON.
  4. Touch "START (NISSAN BASED VHCL)".
    Fig 2: CONSULT-II Function (BCM) - Identifying "START (NISSAN BASED VHCL)"
    G02383948Courtesy of NISSAN MOTOR CO., U.S.A.
  5. Touch C.

    If "BCM" is not indicated, go to "CONSULT-II DATA LINK CONNECTOR (DLC) CIRCUIT ".

    Fig 3: CONSULT-II Function (BCM) - Identifying "BCM"
    G02383949Courtesy of NISSAN MOTOR CO., U.S.A.
  6. Touch "REAR DEFOGGER".
    Fig 4: CONSULT-II Function (BCM) - Identifying "REAR DEFOGGER"
    G02383950Courtesy of NISSAN MOTOR CO., U.S.A.
  7. Select diagnosis mode, "DATA MONITOR" and "ACTIVE TEST".
    Fig 5: CONSULT-II Function (BCM) - Identifying "DATA MONITOR" And "ACTIVE TEST"
    G02383951Courtesy of NISSAN MOTOR CO., U.S.A.