FixVault

Terminals and Reference Value for Combination Meter

TERMINALS REFERENCE VALUE CHART

Terminal No. Wire color Item Condition Reference value
Ignition switch Operation or condition
1 G Vehicle speed signal (8-pulse) ON Speedometer operated [When vehicle speed is approx. 40 km/h (25 MPH)]
NOTE: Maximum voltage may be 5 V due to specifications (connected units).
G04079168
4 LG ACC power supply ACC - Battery voltage
5 B Ground ON - Approx. 0 V
6
7 G/Y Ignition power supply ON - Battery voltage
8 R/W Battery power supply OFF - Battery voltage
13 L/B TX communication line (To unified meter and A/C amp.) ON -
G04078437
14 PU RX communication line (From unified meter and A/C amp.) ON -
G04078438
15 B Ground ON - Approx. 0 V
25 - Illumination control switch (-) OFF Illumination control switch (-) is pressed. Approx. 0 V
Illumination control switch (-) is released. Approx. 5 V
26 - Illumination control switch (+) OFF Illumination control switch (+) is pressed. Approx. 0 V
Illumination control switch (+) is released. Approx. 5 V
27 - ODO/trip meter and illumination control switch ground OFF - Approx. 0 V
35 - Trip reset switch OFF Trip reset switch is pressed Approx. 0 V
Trip reset switch is released Approx. 5 V
36 - Trip transfer switch OFF Trip transfer switch is pressed Approx. 0 V
Trip transfer switch is released Approx. 5 V