TERMINALS REFERENCE VALUE CHART

Terminal No. Wire color Item Measuring condition Reference value
Ignition switch Operation or condition
5 B Ground ON - Approx. 0 V
6
7 G/Y Ignition power supply ON - Battery voltage
8 R/W Battery power supply OFF - Battery voltage
9 LG Seat belt buckle switch (Driver side) ON Unfastened (ON) Approx. 0 V
Fastened (OFF) Approx. 12 V
13 L/B TX communication line (To unified meter and A/C amp.) ON -
G04078437
14 PU RX communication line (From unified meter and A/C amp.) ON -
G04078438