FixVault

Operation mode

  1. Normal status
    • When BCM is not in sleep status, OUTPUT terminals (1-5) send out ON signal every 10 ms.
  2. Sleep status
    • When BCM is in sleep status, transistors of OUTPUT 1 and 5 stop the output, and BCM enters low power mode. Mean while OUTPUT 2, 3, and 4 send out ON signal every 60 ms, and accept only input from lighting switch system.
      Fig 1: Combination Switch Timing Chart
      G04124043Courtesy of NISSAN MOTOR CO., U.S.A.