FixVault

Terminals and Reference Value for IPDM E/R

TERMINALS AND REFERENCE VALUE FOR IPDM E/R

Terminal No. Wire color Item Condition Voltage (V) (Approx.)
Push-button ignition switch position Operation or conditions
4 W/R Starter motor power supply LOCK - 0
START Starter motor is activating Battery voltage
49 L CAN H - - -
50 P CAN L - - -
53 GR/R Shift position signal ON A/T selector lever is in N or P position Battery voltage
LOCK A/T selector lever is in any position other than P and N position 0