TERMINALS AND REFERENCE VALUE CHART

Terminal Wire Color Item Condition Voltage (V) (Approx.)
38 B Ground - 0
39 L CAN-H - -
40 P CAN-L - -
45 G/W Horn relay When doors locks are operated using keyfob (OFF --> ON) (1) Battery voltage --> 0
59 B Ground - 0
(1) when horn reminder is ON.