FixVault

CONSULT-II Reference Value in Data Monitor Mode

WARNING: This page is about a different car, the 2006 Infiniti QX56. However, it is still accessible from the selected car via links, so may be relevant.

Specification data are reference values.

CONSULT II DATA MONITOR MODE REFERENCE VALUE

MONITOR ITEM CONDITION SPECIFICATION
ACCEL SEN 1
  • Ignition switch: ON

    (Engine stopped)

Accelerator pedal: Fully released 0.5 - 1.0V
Accelerator pedal: Fully depressed 4.2 - 4.8V
ACCEL SEN 2(1)
  • Ignition switch: ON

    (Engine stopped)

Accelerator pedal: Fully released 0.5 - 1.0V
Accelerator pedal: Fully depressed 4.2 - 4.8V
CLSD THL POS
  • Ignition switch: ON

    (Engine stopped)

Accelerator pedal: Fully released ON
Accelerator pedal: Slightly depressed OFF
(1) Accelerator pedal position sensor 2 signal is converted by ECM internally. Thus, it differ from ECM terminal voltage.