FixVault

Diagnostic Procedure

  1. CHECK POWER SUPPLY CIRCUIT 

    With CONSULT-II 

    Check ("IGN ON SW") in DATA MONITOR mode with CONSULT-II.

    When ignition switch is turned to ON IGN ON SW: ON 

    Fig 1: Display DATA MONITOR Mode
    G04145326Courtesy of NISSAN MOTOR CO., U.S.A.

    Without CONSULT-II 

    Check voltage between Intelligent Key unit connector and ground.

    VOLTAGE SPECIFICATIONS

    Terminals Ignition switch condition Voltage (V) (Approx.)
    (+) (-)
    Intelligent Key unit connector Terminal
    M32 31 Ground ON Battery voltage
    OFF 0
    Fig 2: Checking Voltage Between Intelligent Key Unit Connector And Ground
    G04145327Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    OK: Check the condition of harness and connector. If it is OK, check the self-diagnosis results using CONSULT-II again.