FixVault

Terminals and Reference Value for BCM

TERMINALS AND REFERENCE VALUE FOR BCM

Terminal No. Wire color Item Condition Reference value (Approx.)
Ignition switch Operation or condition
2 L/R Combination switch input 5 ON Lighting switch is 1ST position (Wiper dial position 4)
G04140619
Lighting switch is OFF position 0 V
33 GR Combination switch output 4 ON Lighting switch is 1ST position (Wiper dial position 4)
G04084542
Lighting switch is OFF position
G04078527
37 LG Key switch signal OFF Intelligent Key is inserted into key slot 12 V
Intelligent Key is removed from key slot 0 V
38 W Ignition switch ON or START ON - Battery voltage
39 L CAN H - - -
40 P CAN L - - -
42 P Battery power supply OFF - Battery voltage
52 B Ground ON - 0 V
55 W Battery power supply OFF - Battery voltage
62 V Front door switch (driver side) OFF When driver side door is opened (Door switch ON) 0 V
When driver side door is closed (Door switch OFF) 12 V