Engine Control System - VK45DE - M45 - System & Component Checks, Service Data And Specifications (SDS)
›
Variable Induction Air Control System (VIAS)
›
CONSULT-II Reference Value in Data Monitor Mode
CONSULT-II Reference Value in Data Monitor Mode
MONITOR ITEM CONDITION CHART
MONITOR ITEM
CONDITION
SPECIFICATION
VIAS S/V
Selector lever: P or N
ON
Engine speed: More than 5,000 rpm
Selector lever: Except P or N
Engine speed: Less than 5,000 rpm