Check Hazard Reminder Operation
- CHECK BCM OUTPUT SIGNAL
- Remove electronic key from ignition key cylinder.
- Check the signal between combination flasher unit connector and ground with oscilloscope.CONNECTOR SIGNAL CHART
Connector Terminal (Wire color) Condition Signal (Reference value) (+) (-) M19 6 (W/L) Ground LOCK switch ON with electronic key UNLOCK switch ON with electronic key*
*: In the state that hazard reminder operates.
OK or NG
- OK : Check combination flasher unit. Refer to "TURN SIGNAL AND HAZARD WARNING LAMPS ".
- NG : GO TO 2.
- CHECK COMBINATION FLASHER UNIT CIRCUIT
- Disconnect BCM and combination flasher unit connector.
- Check continuity between BCM connector M4 terminal 7 and combination flasher unit connector M91 terminal 6.
7 (W/L) - 6 (W/L) : Continuity should exist.
- Check continuity between BCM connector M4 terminal 7 and ground.
7 (W/L) - Ground : Continuity should not exist.
OK or NG
- OK : Replace BCM.
- NG : Repair or replace harness.