Hazard Only Mode

When the LOCK button is pushed, the hazard warning lamp flashes twice.

When the UNLOCK button is pushed, neither the hazard warning lamp nor the hone operates.

OPERATING FUNCTION OF HAZARD AND HORN REMINDER

MODE (Push "LOCK" and "UNLOCK" buttons for more than 2 seconds to switch) Switching indicator LOCK UNLOCK
Hazard and horn --> Hazard only Hazard - 3 times Hazard - twice No operation
Hazard only --> Hazard and horn Hazard - once
Horn - once
Hazard - twice
Horn - once
Hazard - once