Trunk Lid Lock Switch Check
- TRUNK LID LOCK SWITCH SIGNAL CHECK
- Turn ignition switch OFF.
- Check voltage between trunk closure control unit connector and ground.CONNECTOR VOLTAGE CHART
Terminals Condition Voltage (V) (Approx.) ( + ) ( - ) Connector Terminal (Wire color) Ground B56 1 (P) Engage the latch of trunk lock (OFF) Battery voltage Other than the above (ON) 0
OK or NG
- OK : Trunk lid lock switch is OK.
- NG : GO TO 2.
- TRUNK LID LOCK SWITCH CIRCUIT CHECK
- Disconnect trunk closure control unit and trunk lid lock switch connector.
- Check continuity between trunk closure control unit connector B56 terminal 1 and trunk lid lock switch connector B312 terminal 1.
1 (P) - 1 (P) : Continuity should exist.
OK or NG
- OK : GO TO 3.
- NG : Repair or replace harness.
- TRUNK LID LOCK SWITCH GROUND CIRCUIT CHECK
Check continuity between trunk lid lock switch connector B312 terminal 2 and ground.
2 (B/W) - Ground : Continuity should exist.
OK or NG
- OK : GO TO 4.
- NG : Repair or replace harness.
- TRUNK LID LOCK SWITCH CHECK
Check continuity between trunk lid lock switch terminals 1 and 2.
CONTINUITY CHARTTerminals Condition Continuity 1 2 Trunk is closed No Trunk is opened Yes OK or NG
- OK : Replace trunk closure control unit.
- NG : Replace trunk lid lock switch.