FixVault

Terminals and Reference Values for Voice Activated Control Module

TERMINALS AND REFERENCE VALUES FOR VOICE ACTIVATED CONTROL MODULE

Terminal No. (Wire color) Item Condition Reference value (V)
(+) (-) Ignition switch Operation
8 (L/W)(1) Ground TEL ON signal ON While using hands-free phone system or voice activated control system Approx. 0 V
Except while using hands-free phone system and voice activated control system Approx. 12 V
10(1) - Shield - - -
12 (P)(1) 11 (L)(1) TEL voice signal ON Receiving the party's voice while using the hands-free phone system.
G04084885
13 (SB) Ground Battery power source OFF - Battery voltage
14 (B) Ground ON - Approx. 0
20 (L/OR) Ignition switch ACC ACC - Battery voltage
23 Audio shield ground ON - Approx. 0
25 (L) 23 Audio output (-) ON Voice guide operates.
G04131316
26 (R) 23 Audio output (+) ON
27 (Y/R) Ground Mute ON PTT switch (not operate --> operate) Approx. 5 --> Approx. 0
34 (R/W) 33 (L) Mic input ON Voice mic test operates.
G04131317
35 (PU) Ground Communication signal (-) ON -
G04131318
36 (LG) Ground Communication signal (+) ON -
G04131319
37 - Shield - - -
38 (PU)(1) Ground Communication signal (-) ON -
G04131320
39 (LG)(1) Ground Communication signal (+) ON -
G04131321
40(1) - Shield - - -
(1) With NAVI