Check Fuel Level Sensor Unit and Fuel Pump

Check resistance between fuel level sensor unit and fuel pump connector terminals 2 and 5.

RESISTANCE TERMINAL REFERENCE

Terminals Float position mm (in) Resistance value Ω (Approx.)
2 5 (1) Empty 25.86 (1.02) 81.66
(2) Full 254.6 (10.02) 6.98
(1) When float rod is in contact with stopper.
(2) When float rod is in contact with stopper.
Fig 1: Identifying Resistance Between Fuel Level Sensor Unit And Fuel Pump Connector Terminals 2 And 5
G04136355Courtesy of NISSAN MOTOR CO., U.S.A.