Terminals And Reference Value For Intelligent Key Unit Input

TERMINAL AND REFERENCE VALUE CHART

Terminal No. Wire color Item Condition Voltage (V) (Approx.)
Push-button ignition switch position Operation or conditions
63 P Stop lamp switch - Brake pedal depressed Battery voltage
Brake pedal released Battery voltage
29 V/R Stop lamp switch - Brake pedal depressed Battery voltage
Brake pedal released 0