A/T Fluid Temperature Sensor 1

  1. Remove control valve with TCM. Refer to "CONTROL VALVE WITH TCM AND A/T FLUID TEMPERATURE SENSOR 2 ".
  2. Check resistance between terminals.
    RESISTANCE REFERENCE

    Item Connector Terminal Temperature °C (°F) Resistance (Approx.)
    A/T fluid temperature sensor 1 F505 6 - 7 0 (32) 15 kΩ
    20 (68) 6.5 kΩ
    80 (176) 0.9 kΩ
    Fig 1: Measuring Resistance Between A/T Fluid Temperature Sensor Connector Terminals
    G04875868
  3. If NG, replace the control valve with TCM. Refer to "CONTROL VALVE WITH TCM AND A/T FLUID TEMPERATURE SENSOR 2 ".