FixVault

Component Function Check

  1. CHECK POWER WINDOW SWITCH OUTPUT SIGNAL 

    Check ("CDL LOCK SW", "CDL UNLOCK SW") in "DATA MONITOR" mode for "POWER DOOR LOCK SYSTEM" with CONSULT-III. Refer to CONSULT-III FUNCTION (BCM - DOOR LOCK) .

    DATA MONITOR REFERENCE

    Monitor item Condition
    CDL LOCK SW LOCK : ON
    UNLOCK : OFF
    CDL UNLOCK SW LOCK : OFF
    UNLOCK : ON

    Is the inspection result normal? 

    YES: Power window serial link is OK.

    NO: Refer to DIAGNOSIS PROCEDURE  .