FixVault

Component Inspection

  1. CHECK EXHAUST VALVE TIMING CONTROL MAGNET RETARDER
    1. Turn ignition switch OFF.
    2. Disconnect exhaust valve timing control magnet retarder harness connector.
    3. Check resistance between exhaust valve timing control magnet retarder terminals as follows.
      RESISTANCE SPECIFICATIONS

      Terminals Resistance
      1 and 2 9.0 - 11.0 Ω [at 20°C (68°F)]

    Is the inspection result normal? 

    YES: INSPECTION END

    NO: GO TO 2.

  2. REPLACE EXHAUST VALVE TIMING CONTROL MAGNET RETARDER
    1. Replace malfunctioning exhaust valve timing control magnet retarder.
    2. Perform "EXHAUST VALVE TIMING CONTROL LEARNING : SPECIAL REPAIR REQUIREMENT ".

      INSPECTION END