  1. CHECK PUSH-BUTTON IGNITION SWITCH
  1. Turn ignition switch OFF.
  2. Disconnect push-button ignition switch connector.
  3. Check continuity between push-button ignition switch terminals under the following conditions.
CONTINUITY CHART

Push-button ignition switch Condition Continuity
Connector Terminal
M50 1 4 Pressed Existed
Not pressed Not existed

Is the inspection result normal? 

YES: INSPECTION END