Component Function Check
- CHECK FUNCTION
- Select "TILT SW-UP", "TILT SW-DN" in "Data monitor" mode with CONSULT-III.
- Check tilt switch signal under the following conditions.MONITOR ITEM CONDITION CHART
Monitor item Condition Status TILT SW-UP Tilt switch (up) Operate ON Release OFF TILT SW-DN Tilt switch (down) Operate ON Release OFF
Is the indication normal?
YES: INSPECTION END
NO: Perform diagnosis procedure. Refer to , "DIAGNOSIS PROCEDURE ".