FixVault

Component Inspection

  1. CHECK SLIDING LIMIT SWITCH
    1. Turn ignition switch OFF.
    2. Disconnect sliding limit switch connector.
    3. Check continuity between sliding limit switch terminals.
      TERMINALS CONTINUITY CHART

      Sliding limit switch Condition Continuity
      Terminal
      4 32 Seat sliding Front edge Not existed
      Other than above Existed

    Is the inspection result normal? 

    YES: INSPECTION END

    NO: Replace sliding limit switch. (Built in seat cushion frame.)