FixVault

Component Function Check

  1. CHECK UNIFIED METER AND A/C AMP. OUTPUT SIGNAL
    1. Connect the CONSULT-III.
    2. Select the "Data Monitor" for the "METER/M&A" and compare the "FUEL METER" monitor value with the fuel gauge reading on the combination meter.
    FUEL GAUGE SPECIFICATIONS

    Fuel gauge pointer Reference value of data monitor [lit.]
    Full Approx. 68.8
    Three quarters Approx. 60
    Half Approx. 39.2
    A quarter Approx. 20.8
    Empty Approx. 5.6

    Does monitor value match fuel gauge reading? 

    YES: INSPECTION END

    NO: Replace combination meter.