FixVault

Component Function Check

  1. CHECK FUNCTION
    1. Select "LIFT FR PULSE" in "Data monitor" mode with CONSULT-III.
    2. Check the lifting sensor (front) signal under the following conditions.
      MONITOR ITEM VALUE CHART

      Monitor item Condition Value
      LIFT FR PULSE Seat lifting (front) Operate (up) Change (increase)
      Operate (down) Change (decrease)
      Release No change

    Is the indication normal? 

    YES: INSPECTION END

    NO: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".