FixVault

Component Function Check

  1. CHECK FUNCTION
    1. Select "RECLN PULSE" in "Data monitor" mode with CONSULT-III.
    2. Check reclining sensor signal under the following conditions.
      MONITOR ITEM VALUE CHART

      Monitor item Condition Value
      RECLN PULSE Seat reclining Operate (forward) Change (increase)
      Operate (backward) Change (decrease)
      Release No change

    Is the indication normal? 

    YES: INSPECTION END

    NO: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".