FixVault

Diagnosis Procedure

  1. CHECK GROUND CONNECTIONS
    1. Turn ignition switch OFF.
    2. Loosen and retighten three ground screws on the body.

      Refer to "GROUND INSPECTION ".

      Fig 1: Identifying Body Ground Screw
      G05739537Courtesy of NISSAN MOTOR CO., U.S.A.

    OK or NG 

    OK: GO TO 2.

    NG: Repair or replace ground connections.

  2. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
    1. Disconnect EVAP control system pressure sensor harness connector.
      Fig 2: Applying Battery Voltage Between Terminals Of EVAP Canister Vent Control Valve
      G05739538Courtesy of NISSAN MOTOR CO., U.S.A.
    2. Check sensor harness connector for water.

      Water should not exist. 

    OK or NG 

    OK: GO TO 3.

    NG: Repair or replace harness connector.

  3. CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR

    Refer to "COMPONENT INSPECTION ".

    OK or NG 

    OK: GO TO 4.

    NG: Replace EVAP control system pressure sensor.

  4. CHECK INTERMITTENT INCIDENT

    Refer to "HOW TO CHECK TERMINAL " and "INTERMITTENT INCIDENT ".

    For wiring diagram, refer to "DIAGNOSIS PROCEDURE ".

    INSPECTION END