FixVault

Component Function Check

  1. CHECK FUNCTION
  1. Turn ignition switch ON.
  2. Select "DETENT SW" signal in "Data monitor" mode with CONSULT-III.
  3. Check detention switch signal under the following conditions.
DATA MONITOR REFERENCE

Monitor item Condition Status
DETENT SW Selector lever P position OFF
Other than above ON

Is the indication normal? 

YES: INSPECTION END

NO: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".