FixVault

Component Inspection

  1. CHECK HOOD SWITCH
    1. Turn ignition switch OFF.
    2. Disconnect hood switch connector.
    3. Check continuity between hood switch terminals.
      CONTINUITY CHART

      Hood switch Condition Continuity
      Terminal
      1 2 Hood Close the hood Not existed
      Open the hood Existed

      Is the inspection result normal? 

      YES: INSPECTION END

      NO: Replace hood lock (RH). Refer to "HOOD LOCK CONTROL : REMOVAL AND INSTALLATION ".