FixVault

Component Inspection (Condenser)

  1. CHECK CONDENSER
  1. Turn ignition switch OFF.
  2. Disconnect condenser harness connector.
  3. Check resistance between condenser terminals as per the following.
RESISTANCE REFERENCE

Terminals Resistance (MΩ)
1 and 2 Above 1 [at 25°C (77°F)]

Is the inspection result normal? 

YES: INSPECTION END

NO: Replace condenser.