FixVault

Intelligent Key Battery Inspection

Check by connecting a resistance (approximately 300Ω) so that the current value becomes about 10 mA.

Standard: Approx. 2.5 - 3.0V 

Fig 1: Checking Intelligent Key Battery Voltage
G04888199Courtesy of NISSAN MOTOR CO., U.S.A.