Component Function Check
- CHECK FUNCTION
- Select "LIFT FR PULSE" in "Data monitor" mode with CONSULT-III.
- Check the lifting sensor (front) signal under the following conditions.DATA MONITOR
Monitor item Condition Value LIFT FR PULSE Seat lifting (front) Operate (up) Change (increase) Operate (down) Change (decrease) Release No change Is the indication normal?
YES: Inspection End.
No: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".