FixVault

Component Function Check

  1. CHECK FUNCTION
    1. Select "LIFT FR PULSE" in "Data monitor" mode with CONSULT-III.
    2. Check the lifting sensor (front) signal under the following conditions.
      DATA MONITOR

      Monitor item Condition Value
      LIFT FR PULSE Seat lifting (front) Operate (up) Change (increase)
      Operate (down) Change (decrease)
      Release No change

      Is the indication normal? 

      YES: Inspection End.

      No: Perform diagnosis procedure. Refer to "DIAGNOSIS PROCEDURE ".