FixVault

Component Function Check

  1. CHECK FUNCTION 
    1. Turn ignition switch ON.
    2. Select "DETENT SW" signal in "Data monitor" mode with CONSULT-III.
    3. Check detention switch signal under the following conditions.
    DATA MONITOR REFERENCE

    Monitor item Condition Status
    DETENT SW Selector lever P position OFF
    Other than above ON

    Is the indication normal? 

    YES: INSPECTION END

    NO: Perform diagnosis procedure. Refer to DIAGNOSIS PROCEDURE .