FixVault

Battery Current Sensor

  1. Reconnect harness connectors disconnected.
  2. Disconnect battery negative cable (1).
  3. Install jumper cable (A) between battery negative terminal and body ground.
  4. Turn ignition switch ON.
    Fig 1: Identifying Battery Negative Cable And Jumper Cable
    G06315732Courtesy of NISSAN MOTOR CO., U.S.A.
  5. Check voltage between ECM terminal 71 (battery current sensor signal) and ground.

    Voltage: Approximately 2.5V 

  6. If NG, replace battery negative cable assembly.
    Fig 2: Checking Voltage Between ECM Terminal 71 (Battery Current Sensor Signal) And Ground
    G06315733Courtesy of NISSAN MOTOR CO., U.S.A.