With CONSULT-III

Perform the "GAS SENSOR ADJUSTMENT" of HVAC work support item.

WORK SUPPORT ITEM

Work support items Display Setting
GAS SENSOR ADJUSTMENT 2 Less sensitive setting than display 1 (REC later than display 1.)
1 Less sensitive setting than normal setting (REC later than normal operation.)
0 (initial status) Normal
-1 More sensitive setting than normal setting (REC earlier than normal operation.)
-2 More sensitive setting than display -1 (REC earlier than display -1.)
NOTE: When the battery cable is disconnected from the negative terminal or when the battery voltage becomes 10 V or less, the setting of WORK SUPPORT may be cancelled.