FixVault

Work Procedure

  1. ACTIVATE OPERATION
    1. Select "WORK SUPPORT" item "ACTIVATE OPERATION" of SIDE RADAR (LEFT, RIGHT) with CONSULT-III.
    2. Select "Activate".
    3. Check that "DATA MONITOR" item "ACTIVATE OPE" is changed to "On".
    4. Turn ignition switch OFF.

      GO TO 2.

  2. PERFORM SELF-DIAGNOSIS
    1. Turn ignition switch ON.
    2. Perform the self-diagnosis of side radar with CONSULT-III. Check if any DTC is detected.

      Is any DTC detected? 

      YES: Perform the trouble diagnosis for the detected DTC. Refer to "DTC INDEX ".

      NO: GO TO 3.

  3. BSW WARNING LAMP CHECK
    1. Perform the BSW system action test. Refer to "DESCRIPTION ".
    2. Check that BSW system operates normally.

      WORK END