FixVault

Component Inspection (Stop Lamp-Switch)

  1. CHECK STOP LAMP SWITCH Check continuity between stop lamp switch connector terminals.
    Stop lamp switch connector Condition Continuity
    Connector Terminal
    E110 3 4 Depressed brake pedal. Existed
    Released brake pedal. Not existed

    Is the inspection result normal? 

    YES: INSPECTION END

    NO: Replace stop lamp switch. Refer to "EXPLODED VIEW ".